2015年6月23日星期二

Fault Analysis Magnetic Separator


(1) magnetic separator machine motor overheating and noise is not normal.
Magnetic separator machine motor overheating and noise is not normal reasons: 1) poor or badly worn bearing lubrication; 2) fan leaves fall off or wear; 3) switch circuit connection. Bad touch, or break run single phase; 4) voltage is too low.
(2) Separator abnormal sound in operation, the cylinder stuck obstacles, even the cylinder can not be rotated, the bottom box fibrillation.
The reason is often jammed base box object, then there are magnetic liquid trap off, so that the cylinder rattled serious cause tube skin scratched. At this time you should shut down for maintenance 􀂨 troubleshooting.
(3) Deceleration overheating
The reasons: 1) lack of or poor fuel oil; 2) wear off even with the worm gear, or engaging well; 3) poor bearing lubrication or badly worn.
(4) super neodymium magnets field strength becomes weaker
The reasons: 1) high temperature; 2) sun exposure; 3) acid corrosion. You can use Gauss meter. Magnetic separator from the base, under the magnetic system, the tumble, the magnetic system, hollow shaft, concentrate tank, gears and other components. Installed base with hollow bearing seat as a benchmark to measure the elevation and levelness. Positioned under the magnetic system to stand as a benchmark. Cage and the upper and lower magnetic gap adjustment system must be accurate, the gap deviation limit hand 0 + 1mm.